SKU Fractional CO2 Laser with metal RF tube Categories ,
Facebook
Pinterest
WhatsApp

Fractional CO2 Laser with metal RF tube

Key benefits:

  • Select healing zone volume (Density)
  • Select volume treated (Spot Size)
  • Select target depth (Epidermal or Dermal)
  • Immediate results (Damaged skin removal)
  • Continued long-term improvement (Collagen remodeling and Neocollagenesis)

 

 

Customization:

Hygea Technology helps you collect and review requirements.

Warranty: 2 years

We offer the option of the service even after the warranty expires

Description

Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth, and density that are surrounded by a reservoir of spared epidermal and dermal tissue, allowing for rapid repair of laser-induced thermal injury. This unique modality, if implemented with proper laser-delivery systems, enables high-energy treatments while minimizing risks.

 

Scanners (scanning size maximum 20*20 mm) and cutting surgical heads

Scanners and Cutting Surgery Heads

 

Vaginal Heads & Digital Endoscope

Vaginalne glave in digitalni endoskop

Scanning

Scan size and shape: Healing zone selecting matches to each patient’s needs. Leave 95% to 0% intact.

Scan density: Shape(Ellipse, Rectangular, Triangular, Line, Square, hexagon, round) and Size(single pulse scanning maximum 20*20mm adjustable).

Scanning Depth: Select target depth (Epidermal or Dermal) from 20um-2000um (adjustable).

Skeniranje

Notice Before Treatment:

  • The patient should not take any medications containing aspirin (acetylsalicylic acid), high doses of vitamin E, eating garlic, consuming alcohol and smoking at least 2 weeks before and after the treatment.
  • The surgeon will decide whether preliminary examinations are necessary, such as blood tests, an electrocardiogram, or x-rays of the lungs. If this is the case, these tests should be performed 2 weeks before the surgery.
  • It is best not to wear any makeup when the client comes in for the operation.
  • Wear loose clothing that doesn't need to be pulled over head.
  • Wear loose clothing that doesn't need to be pulled over head.
  • Do not eat or drink anything for 6 hours before your operation.

 

Specifications:

  • Output power: 30W
  • Focal length of working head: F=50mm, 75mm, 100mm
  • Indication Beam: Red diode laser (650nm, ≤5mW)
  • Transmission System: 7-Articulation Joint Spring Arm
  • Smoke Exhausting System: Built-in ventilation
  • Cooling system: Air cooling
  • Environmental temperature: 5°C~40°C
  • Relative Humidity: ≤80%
  • Energy supply: ~220V±22V,50Hz±1Hz
  • Dimensions: 52*68*132cm
  • Weight: 35kg

 

Working mode:

  • Interval time: 1~999ms
  • Pulse: Power 1~30 W (adjustable)
  • Ultra pulse: Power 1 ~ 30 W (adjustable) / Modulated frequency 1000 Hz
  • Pulse Duration: 90-1000μs

 

Scanning mode:

  • Scanning mode: Ellipse, Rectangular, Triangular, Line, Square, hexagon, round
  • Repeat Delay: 0.1s—- 5.0s
  • Micro Pulse Energy: 5mJ—50mJ
  • Treatment Level: 0.30%–25.0%
  • Passes: 1–10-krat
  • Estimated Power: 24mJ–1000J
  • Ellipes estimated power: 31mJ—1000J
  • Rectangular estimated power: 24mJ—981J
  • Treatment area: 0.1*0.1mm—15*15mm
  • Handpiece Velocity: 0.1–9cm2/s
  • Scanning Depth: ≤2.0mm

 

Vaginal Mode:

  • Working mode: 360 degree revolution
  • Treatment depth: 100mm
  • Treatment head diameter: 30mm
  • Max Scanning diameter: 9*9mm2
  • Spot Size Diameter: 0.2-1.0mm
  • Focus length: 150mm
  • Parameter setting: 30-40mj/pin

 

Product
E-mail
Phone
Enquiry

CONTACT US FOR MORE INFORMATION

en_GBEnglish (UK)